Dow-Key Microwave MS-1U18S-4 Manual del operador Pagina 54

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 65
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 53
48
Remote Operation
6.6.2 Setting switch x to position n
x = switch [module] address.
n = position to set and must be within the switches parameter.
(Example: SP10T valid positions are 0 thru 10 only).
Examples:
ROUTE:SWITCHx n
ROUT:SWITCHx n
ROUTE:SWITx n
ROUT:SWITx n
:SWITCHx n
:SWITx n
ROUTE:SWITCHx:VALUE n
ROUTE:SWITCHx:VAL n
:SWITx:VAL n
Possible error codes
5, 10, 12, 13
Factory default value
N.a.
Power on behavior
Keeps last value
*RST effect
SP6T switch: will open all positions
Transfer switch: will close position 1
Timing
The timing to execute a command depends on the length of the command (in
case of concatenated commands).
As a rule of thumb electromechanical switches require approximately 30ms to
switch position. It is safe to consider some safety margin and increase this
timing to 40-50 ms when developing the control software.
Multiple switch commands are not executed in a sequential manner but rather
in parallel.
Vista de pagina 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 64 65

Comentarios a estos manuales

Sin comentarios